Product name : (PSA) Prostate Specific Antigen Semi-Quantitative Test Strip PSA-W01QB
Item : PSA-W01QB
 Enlarge Image                   Back
←[Previous Product]              [Next Product]→


Details:

Product Name 

Specimen 

Format 

Catalog No. 

Cut-off(ng/ml) 

Strip width 

Certificate 

(PSA)Prostate Specific Antigen Semi-Quantitative

Whole blood/serum

Strip

PSA-W01QB

10

3.0mm

CE

PSA-W01QD

4.0mm

 

Specifications

psa test strip 

format:strip

Model No:PSA-W01QB

high sensitivity

 

Intended Use

One Step PSA Rapid Screen Test is a rapid direct binding immunoassay in-vitro diagnostic (IVD) test for the qualitative detection of Prostate Specific Antigen (PSA) tumor markers in human Whole blood. PSA tumor marker tests are based on the principle of sandwich immunoassay for determination of PSA in human Whole Blood. Two monoclonal antibodies are employed to identify cancer PSA specifically. The prostate specific antigen (PSA) is the most commonly tested tumor marker for the prostate gland disease diagnosis. PSA tumor marker is normally present in low levels in the blood of all adult men. In human blood, the normal concentration range of this biomarker is 0.0 to 4.0 ng/ml, which are variable among different human races (refer to the table at the end of this page). But when prostate specific antigen rise beyond 

the normal range, it can be taken as a signal of prostate gland cancer or other problems. That is why PSA becomes the subject of PSA Whole Blood detection devices.

TEST PROCEDURE

  1. Do not open foil pouch until ready to begin testing.  Refrigerated test devices should be allowed to come to room temperature (15°- 28°C) before opening the pouch. 
  2. Remove the device from the protective pouch and label the device with specimen identification.  
  3. Add 50 ul of fresh blood to the Sample Well (for Card) or Sample Pad (for Dipstick),Then add 2 drops (50 ul) of test running buffer into the sample well or sample pad.
  4. Read the result within10-15 minutes. Do not read results after 15 minutes. Observe the colored band developed over the control region indicating the assay is complete.

Related Products :
(PSA) Prostate Specific Antigen Semi-Quantitative Test Cassette PSA-P02QD
PSA-P02QD
(PSA) Prostate Specific Antigen Semi-Quantitative Test Cassette PSA-P02QD
(PSA) Prostate Specific Antigen Semi-Quantitative Test Cassette PSA-P02QB
PSA-P02QB
(PSA) Prostate Specific Antigen Semi-Quantitative Test Cassette PSA-P02QB
(PSA) Prostate Specific Antigen Semi-Quantitative Test Strip PSA-P01QD
PSA-P01QD
(PSA) Prostate Specific Antigen Semi-Quantitative Test Strip PSA-P01QD
(PSA) Prostate Specific Antigen Semi-Quantitative Test Strip PSA-P01QB
PSA-P01QB
(PSA) Prostate Specific Antigen Semi-Quantitative Test Strip PSA-P01QB
(PSA) Prostate Specific Antigen Semi-Quantitative Test Cassette PSA-W02QD
PSA-W02QD
(PSA) Prostate Specific Antigen Semi-Quantitative Test Cassette PSA-W02QD
(PSA) Prostate Specific Antigen Semi-Quantitative Test Cassette PSA-W02QB
PSA-W02QB
(PSA) Prostate Specific Antigen Semi-Quantitative Test Cassette PSA-W02QB
(PSA) Prostate Specific Antigen Semi-Quantitative Test Strip PSA-W01QD
PSA-W01QD
(PSA) Prostate Specific Antigen Semi-Quantitative Test Strip PSA-W01QD
(CEA) Carcinoembryonic Antigen Test Cassette CEA-P02D
CEA-P02D
(CEA) Carcinoembryonic Antigen Test Cassette CEA-P02D